Title of article
Effects of ozonation on the permeate flux of nanocrystalline ceramic membranes
Author/Authors
Bhavana S. Karnik، نويسنده , , Simon H.R. Davies، نويسنده , , Kuan C. Chen، نويسنده , , David R. Jaglowski، نويسنده , , Melissa J. Baumann، نويسنده , , S.J. Masten، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
7
From page
728
To page
734
Abstract
Titania membranes, with a molecular weight cut-off of 15 kD were used in an ozonation/membrane system that was fed with water from Lake Lansing, which had been pre-filtered through a 0.45 μm glass fiber filter. The application of ozone gas prior to filtration resulted in significant decreases in membrane fouling. The effects of ozonation could not be explained by physical scouring of the filter cake. Decrease in the pH resulted in a concomitant increase in the dissolved ozone concentration in the feed water and in an improvement in permeate flux recovery. Increasing the ozone concentration beyond a threshold value had no beneficial effect on permeate flux recovery. Ozone decomposition, resulting in the formation of OH or other radicals at the membrane surface, is thought to result in the decomposition of organic foulants at the membrane surface and reduce the extent of membrane fouling.
Keywords
ozonation , Ceramic membranes , Permeate flux , fouling , membrane filtration
Journal title
Water Research
Serial Year
2005
Journal title
Water Research
Record number
772291
Link To Document