• Title of article

    On-line detection of metal pollutant spikes in MSW incinerator flue gases prior to clean-up

  • Author/Authors

    D. Poole، نويسنده , , V. Sharifi، نويسنده , , J. Swithenbank، نويسنده , , B. Argent، نويسنده , , D. Ardelt، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    14
  • From page
    519
  • To page
    532
  • Abstract
    SUWIC’s unique mobile metals emissions monitoring laboratory has been used to measure metal pollutant spikes in the flue gas from a municipal solid waste incinerator, prior to gas clean-up. The laboratory has a heated sampling probe that extends into the plant, allowing the simultaneous on-line measurement of the concentrations of more than 30 metals by Inductively Coupled Plasma–Optical Emission Spectrometry (ICP–OES). As little is known about temporal variation in metal concentrations, this capability is seen as a major advance. The graphs of continuous measurements show that the elemental loading is far from uniform, and that concentrations fluctuate far more than may have been conventionally expected. There are occasional significant spikes in the emission profiles for cadmium and mercury, which are believed to be due to specific items in the waste feed material. Continuous monitoring measurements are of significant value for those seeking to model metal behaviour in combustion and in pollution control devices.
  • Journal title
    Waste Management
  • Serial Year
    2007
  • Journal title
    Waste Management
  • Record number

    775247