Title of article
In vitro monitoring of nanogram levels of puerarin in human urine using flow injection chemiluminescence
Author/Authors
Changna Wang، نويسنده , , Zhenghua Song، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
4
From page
4127
To page
4130
Abstract
A rapid and sensitive chemiluminescence (CL) determination of puerarin with the flow injection technique was presented. It was found that puerarin could enhance the CL generated from luminol–KIO4 system significantly. The increment of CL intensity was linear over the concentration of puerarin ranging from 0.3 to 100.0 ng mL−1 (r2=0.9963), offering a detection limit as low as 0.1 ng mL−1 (3σ). At a flow rate of 2.0 mL min−1, one analysis cycle, including sampling and washing, could be accomplished in 20 s with a relative standard deviation of less than 5.0%. The experimental results demonstrated that the excretive amounts of puerarin reached its maximum in 3 h after taking 250 mL green drink containing 275 mg puerarin, and the puerarin excretive ratio during 24 h was 9.70% in the body of volunteers.
Keywords
Human urine. , Pharmaceuticalinjection , Flow injection , chemiluminescence , Puerarin
Journal title
Bioorganic & Medicinal Chemistry Letters
Serial Year
2004
Journal title
Bioorganic & Medicinal Chemistry Letters
Record number
794747
Link To Document