• Title of article

    Temperature increase in the human head due to a dipole antenna at microwave frequencies

  • Author/Authors

    A.، Hirata, نويسنده , , M.، Morita, نويسنده , , T.، Shiozawa, نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    -108
  • From page
    109
  • To page
    0
  • Abstract
    The temperature increases in a human head due to electromagnetic (EM) wave exposure from a dipole antenna are investigated in the frequency range of 900 MHz to 2.45 GHz. The maximum temperature increases in the head and brain are compared with the values of 10/spl deg/C and 3.5/spl deg/C (found in literature pertaining to microwave-induced physiological damage). In particular, the estimation scheme for maximum temperature increases of the head and brain tissues is discussed in terms of a peak average specific absorption rate (SAR) as prescribed in safety standards. The rationale for this attempt is that maximum temperature increases and peak average SARs have not been well correlated yet. For this purpose, the SAR in the head model is initially calculated by the finite-difference time-domain method. The temperature increase in the model is then calculated by substituting the SAR into the bioheat equation. Numerical results demonstrate that the temperature increase distribution in the head is largely dependent on the frequency of EM waves. This is mainly because of the frequency dependency of the SAR distribution. Similarly, maximum temperature increases in the head and brain are significantly affected by the frequency and polarization of the EM wave. The maximum temperature increases in the head (excluding auricles) and brain are determined through linear extrapolation of the peak average SAR in these regions. According to this scheme, it is found that the peak SAR averaged over 1 g of tissue in the head should be approximately 65 W/kg to achieve the maximum temperature increase of 10/spl deg/C induced in the head excluding auricles. This corresponds to a factor of about 40 compared to the FCC standard. On the other hand, the peak SAR for 10 g of tissue should be around 40 W/kg, which implies a factor of about 20 compared to the ICNIRP standard.
  • Keywords
    Fredholm determinants , semi-separable kernels , Jost functions , Transmission coefficients , Floquet discriminants , Days formula
  • Journal title
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY
  • Serial Year
    2003
  • Journal title
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY
  • Record number

    80050