• Title of article

    Improved p charts to monitor process quality

  • Author/Authors

    ACOSTA-MEJIA، CESAR A. نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    -508
  • From page
    509
  • To page
    0
  • Abstract
    It is a common practice to monitor the fraction p of non-conforming units to detect whether the quality of a process improves or deteriorates. Users commonly assume that the number of non-conforming units in a subgroup is approximately normal, since large subgroup sizes are considered, lf p is small this approximation might fail even for large subgroup sizes. If in addition, both upper and lower limits are used, the performance of the chart in terms of fast detection may be poor. This means that the chart might not quickly detect the presence of special causes. In this paper the performance of several charts for monitoring increases and decreases in p is analyzed based on their Run Length (RL) distribution. It is shown that replacing the lower control limit by a simple runs rule can result in an increase in the overall chart performance. The concept of RL unbiased performance is introduced. It is found that many commonly used p charts and other charts proposed in the literature have RL biased performance. For this reason new control limits that yield an exact (or nearly) RL unbiased chart are proposed.
  • Keywords
    Extraction kinetics , Aliquat 336 , LIX 63 , PALLADIUM
  • Journal title
    IIE TRANSACTIONS
  • Serial Year
    1999
  • Journal title
    IIE TRANSACTIONS
  • Record number

    8071