Title of article
The sensitivity of transesophageal pacing for screening in atrial tachycardias
Author/Authors
Milos Kesek، نويسنده , , Hormoz Sheikh، نويسنده , , Hamid Bastani، نويسنده , , Per Blomstr?m، نويسنده , , Carina Blomstr?m Lundqvist، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1999
Pages
4
From page
239
To page
242
Abstract
Transesophageal atrial pacing and recording performed in 128 patients for palpitations or tachycardia was retrospectively evaluated and compared to the same procedure in 77 routinely evaluated patients after a catheter ablation procedure. The sensitivity and specificity of the described protocol was 74 and 90% respectively. The procedure was well tolerated and a majority of patients could be completely evaluated according to the protocol. The outcome of the first time investigation influenced the subsequent choice of therapy in the studied population. The results suggest that transesophageal pacing is a valuable tool for evaluation of atrial tachycardias with specificity, sensitivity and tolerability comparable to other noninvasive methods used in cardiology.
Keywords
Supraventricular arrhythmia , screening , tachycardia , Transesophageal pacing