• Title of article

    Adjunctive devices in primary or rescue PCI: A meta-analysis of randomized trials

  • Author/Authors

    Francesco Burzotta، نويسنده , , Luca Testa، نويسنده , , Floriana Giannico، نويسنده , , Giuseppe G.L. Biondi-Zoccai، نويسنده , , Carlo Trani، نويسنده , , Enrico Romagnoli، نويسنده , , Mario Mazzari، نويسنده , , Rocco Mongiardo، نويسنده , , Massimo Siviglia، نويسنده , , Giampaolo Niccoli، نويسنده , , Maria De Vita، نويسنده , , Italo Porto، نويسنده , , Giovanni Schiavoni، نويسنده , , Filippo Crea، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    9
  • From page
    313
  • To page
    321
  • Abstract
    Objectives To overview and summarize the results emerging from the studies on adjunctive devices (AD) with theoretical anti-embolic properties in patients with ST-elevation acute myocardial infarction (STEMI) undergoing percutaneous coronary interventions (PCI). Background A series of small-to-medium size randomized studies have compared different AD with standard PCI (SP) in the setting of STEMI. The reported results are conflicting. Methods Eighteen prospective randomized studies on 3180 STEMI patients comparing AD with SP were identified and entered the meta-analysis. Pre-specified angiographic, electrocardiographic (absence of ST-segment resolution, STR) and early (up to 30 days) clinical end-points were assessed. Results AD were associated with lower rates of angiographically evident distal embolization: OR (95% CI): 0.54 (0.37–0.81). Analyses of angiographic and electrocardiographic reperfusion showed striking heterogeneity among studies and an overall trend toward better results with AD: OR (95% CI) 0.76 (95% CI 0.51–1.12) for TIMI < 3, 0.53 (0.37–0.76) for myocardial blush grade (MBG) < 3, 0.60 (0.45–0.78) for absence of STR. Subgroup analysis according to the type of AD for the end-point of no STR showed concordant absence of benefit in studies testing distal protection devices, positive results being confined to the studies using thrombectomy devices (OR 0.46, 95% CI 0.32–0.66). However, the possibility of a “small study” bias within thrombectomy studies cannot be discharged (significant heterogeneity and positive Eggerʹs test). Early major adverse cardiac events were not different between AD and SP. Conclusions AD use may be associated with reduced rate of angiographic distal embolization, and improved MBG 3 and STR rates. However, efficacy might vary with the type of device employed. Moreover, early clinical outcome is not modified suggesting that further, larger, studies are needed to assess the clinical impact of AD. Condensed abstract We conducted a meta-analysis of 18 prospective randomized trials comparing adjunctive devices (AD) with standard PCI in the setting of STEMI. The use of AD was associated with lower rates of (angiographically evident) distal embolization. Analyses of angiographic and electrocardiographic reperfusion showed striking heterogeneity and an overall trend toward better results with AD. Subgroup analysis suggested that different types of device may have different effects. Early major adverse cardiac events were similar between AD and SP.
  • Keywords
    No-reflow , ST-elevation acute myocardial infarction , PCI , meta-analysis
  • Journal title
    International Journal of Cardiology
  • Serial Year
    2008
  • Journal title
    International Journal of Cardiology
  • Record number