• Title of article

    Applications and limitations of the colloid titration method for measuring activated sludge surface charges

  • Author/Authors

    Mikkelsen، Lene Haugaard نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    -2457
  • From page
    2458
  • To page
    0
  • Abstract
    Surface charge quantification of polymer solutions and sludge suspensions were investigated by the colloid titration technique and compared to charge densities obtained by pH-titration. The colloid titration technique worked well for polymer samples. The charge quantity of humic acid and activated sludge extracellular polymers (EPS) was estimated to be 1.51 and 0.42 meq/g, respectively. These values are reasonable when compared to pH-titration results. The surface charge of activated sludge particles appears to be below the limit of detection. However, surface charge estimates are obtained, when the reactant doses and sample concentration are increased. It is suggested that such estimates are not correct, but artefacts of the nonstoichiometric precipitation of the polymeric reactants at high doses. It appears that the colloid titration method is limited to conditions of low reactant doses and valid for charge determination of extracted sludge polymers, whereas the method is not valid for charge determination of whole sludge.
  • Keywords
    Colloid titration , Surface charge , EPS charge , sludge
  • Journal title
    Water Research
  • Serial Year
    2003
  • Journal title
    Water Research
  • Record number