• Title of article

    Response of piezoresistive MEMS accelerometers and pressure transducers to high gamma dose

  • Author/Authors

    K.E.، Holbert, نويسنده , , J.A.، Nessel, نويسنده , , S.S.، McCready, نويسنده , , A.S.، Heger, نويسنده , , T.H.، Harlow, نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    -1851
  • From page
    1852
  • To page
    0
  • Abstract
    Several piezoresistive microelectromechanical (MEMS) sensors are operated in a gamma ray environment to doses of 800 kGy. The pressure transducers and accelerometers are micromachined silicon-on-insulator (SOI) and bulk silicon devices, respectively. Both sensor types experienced similar performance degradation: a drift in offset voltage with a slight increase in sensitivity. We explain the drift in offset voltage for all sensors tested by correlating the change in resistance of the silicon piezoresistors to the formation of oxide and interface trapped hole charges. We demonstrate how these charges effectively reduce the volume for current flow through the piezoresistors due to the creation of a depletion region surrounding the periphery of the gage resistors. Differences in the magnitude of the output voltage drift of the two sensor types are determined to be related to the unique construction of each sensor.
  • Keywords
    Biodegradable dissolved organic carbon , bioreactor , Cell immobilization , Determination , Continuous
  • Journal title
    IEEE Transactions on Nuclear Science
  • Serial Year
    2003
  • Journal title
    IEEE Transactions on Nuclear Science
  • Record number