• Title of article

    Achieving cost savings through collaborative seismic testing Original Research Article

  • Author/Authors

    Garry Chapman، نويسنده , , John Richards، نويسنده , , Leonard Loflin، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1998
  • Pages
    12
  • From page
    235
  • To page
    246
  • Abstract
    Seismic qualification of nuclear power plant equipment through testing has been perceived by utility personnel as a costly and complicated process. Certainly, some equipment types may only be qualified by test due to the complexity of the item and/or the inability to represent the item in a quantitative analysis. Other factors also influence the reluctance by some to resort to seismic testing. These include cost, dealing with test failures, lack of understanding of the testing process, and greater reliance on new analytical techniques. A group of utilities have allied themselves to address these issues and have formed the Seismic Qualification Reporting and Testing Standardization (SQURTS) group. SQURTS has implemented a program whereby testing is performed at a low cost, often lower than a comparable analytical solution. Testing is conducted at generic seismic levels using generic test procedures, which broadens the applicability of results. Test reports are published in a standard format which shortens the process of review and approval. Testing is no longer just a requirement, but a cost-effective option.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    1998
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number