Title of article
Thermal fatigue strength of type 304 stainless steel in simulated BWR environment Original Research Article
Author/Authors
Makoto Hayashi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
10
From page
135
To page
144
Abstract
Thermal fatigue tests of type 304 stainless steel were performed using thermal fatigue testing apparatus developed in order to clarify thermal fatigue behavior in a BWR environment. Pressurized high and low temperature pure waters were alternately supplied to an autoclave containing a thin-walled cylindrical specimen. The fatigue specimen was then subjected to homogeneous thermal stress through the wall thickness. The thermal fatigue strengths were compared with the mechanical fatigue strength performed in air and in high temperature water. It was found that the thermal fatigue strength of type 304 stainless steels almost agreed with the mechanical fatigue strength when the nominal stress amplitude was converted to a fictitious stress amplitude by using the mean value of strain amplitudes for room temperature and 288°C.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
1998
Journal title
Nuclear Engineering and Design Eslah
Record number
888588
Link To Document