• Title of article

    Air vent in water chamber and surface coating on liner slides concerning auxiliary cooling system for the high temperature engineering test reactor Original Research Article

  • Author/Authors

    Takeshi Takeda، نويسنده , , Kazuhiko Kunitomi، نويسنده , , Minoru Ohkubo، نويسنده , , Toshiji Saito، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1998
  • Pages
    12
  • From page
    229
  • To page
    240
  • Abstract
    Experimental study was made to confirm the validity of new designs of the auxiliary cooling system for the high temperature engineering test reactor (HTTR). First, it is necessary to vent residence air in outlet side of water chamber of the auxiliary heat exchanger for the HTTR. Accordingly, we have proposed to mount a proper bend duct in the outlet side of the water chamber. Air vent is done by difference between pressures at both ends of the bend duct caused by the forced water circulation using the water pumps. From flow tests, it was confirmed that it is capable of venting the air through the bend duct by circulating the water in maximum capacity of the water pumps. Second, it is essential to prevent seizure and excessive wear of the liner slides of the auxiliary concentric hot gas duct for the HTTR at a service temperature of 950°C. Therefore, we have put forward to coat titanium nitride (TiN) on the surface of the liner slides made of nickel-based superalloy Hastelloy XR using the thermochemical vapor deposition method. As a result of seizure and wear tests, it was confirmed that the TiN coating film of 3 μm on the surface of Hastelloy XR is sufficient.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    1998
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    888625