• Title of article

    Scaling analysis for the OSU AP600 test facility (APEX) Original Research Article

  • Author/Authors

    Jose N. Reyes Jr.، نويسنده , , Lawrence Hochreiter، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1998
  • Pages
    57
  • From page
    53
  • To page
    109
  • Abstract
    In this paper, the authors summarize the key aspects of a state-of-the-art scaling analysis (Reyes et al., 1995. Westinghouse Electric Corporation, WCAP-14270) performed to establish the facility design and test conditions for the Advanced Plant Experiment (APEX) at Oregon State University (OSU). This scaling analysis represents the first, and most comprehensive, application of the Hierarchical Two-Tiered Scaling (H2TS) Methodology (Zuber, 1991. US Nuclear Regulatory Commission, Washington DC, NUREG/CR-5809) in the design of an integral system test facility. The APEX test facility, designed and constructed on the basis of this scaling analysis, is the most accurate geometric representation of a Westinghouse AP600 nuclear steam supply system. The OSU APEX test facility has served to develop an essential component of the integral system database used to assess the AP600 thermal hydraulic safety analysis computer codes.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    1998
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    888637