Title of article
Critical heat flux in a vertical tube at low and medium pressures: Part I. Experimental results Original Research Article
Author/Authors
A. Olekhnovitch، نويسنده , , A. Teyssedou، نويسنده , , A. Tapucu، نويسنده , , P. Champagne، نويسنده , , D.C. Groeneveld، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1999
Pages
17
From page
73
To page
89
Abstract
This paper presents experimental CHF data obtained for vertical up flow in an 8 mm I.D. test section, for a wide range of exit qualities (5–75%) and exit pressures ranging from 5 to 40 bar. The experiments were carried out for heated lengths of 0.75, 1, 1.4, 1.8, 2.5 and 3.5 m. A number of different coordinate systems are used to present the experimental results, these include CHF as a function of the inlet subcooling, as a function of the outlet thermodynamic quality, and as a function of the boiling length. An analysis of these commonly used representations of the CHF, has shown, that for all of the cases studied, the critical heat flux is dependent in some manner on the heated length. This dependence greatly complicates the possibility of obtaining a universal correlation for the critical heat flux at low and medium pressures.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
1999
Journal title
Nuclear Engineering and Design Eslah
Record number
888984
Link To Document