• Title of article

    Critical heat flux in a vertical tube at low and medium pressures: Part I. Experimental results Original Research Article

  • Author/Authors

    A. Olekhnovitch، نويسنده , , A. Teyssedou، نويسنده , , A. Tapucu، نويسنده , , P. Champagne، نويسنده , , D.C. Groeneveld، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    17
  • From page
    73
  • To page
    89
  • Abstract
    This paper presents experimental CHF data obtained for vertical up flow in an 8 mm I.D. test section, for a wide range of exit qualities (5–75%) and exit pressures ranging from 5 to 40 bar. The experiments were carried out for heated lengths of 0.75, 1, 1.4, 1.8, 2.5 and 3.5 m. A number of different coordinate systems are used to present the experimental results, these include CHF as a function of the inlet subcooling, as a function of the outlet thermodynamic quality, and as a function of the boiling length. An analysis of these commonly used representations of the CHF, has shown, that for all of the cases studied, the critical heat flux is dependent in some manner on the heated length. This dependence greatly complicates the possibility of obtaining a universal correlation for the critical heat flux at low and medium pressures.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    1999
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    888984