Title of article
Static analytical and experimental research of shock absorber to safeguard the nuclear fuel assemblies Original Research Article
Author/Authors
Gintautas Dundulis، نويسنده , , Albertas Grybenas، نويسنده , , Renatas Karalevicius، نويسنده , , Vidas Makarevicius، نويسنده , , Sigitas Rimkevicius، نويسنده , , Eugenijus Uspuras، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
8
From page
1
To page
8
Abstract
The Ignalina Nuclear Power Plant (NPP) has two RBMK-1500 graphite-moderated boiling water multi-channel reactors. The Ignalina NPP Unit 1 was shutdown at the end of 2004, while Unit 2 is foreseen to be shutdown at the end of 2009. At the Ignalina NPP Unit 1 remains approximately 1000 spent fuel assemblies with low burn-up depth. A special set of equipment was developed to reuse these assemblies in the reactor of Unit 2. One of most important items of this set is a container, which is used for the transportation of spent fuel assemblies between the reactors of Unit 1 and Unit 2. A special shock absorber was designed to avoid failure of fuel assemblies in case of hypothetical spent fuel assemblies drop accident during uploading/unloading of spent fuel assemblies to/from container. This shock absorber was examined by using scaled experiments.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
2009
Journal title
Nuclear Engineering and Design Eslah
Record number
895208
Link To Document