Title of article
Single-stage photodiode op-amp solution suited for a self-mixing FMCW system
Author/Authors
D.، Nordin, نويسنده , , K.، Hyyppa, نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
-181
From page
182
To page
0
Abstract
The current delivered by the photodiode in a self-mixing frequency modulated continuous wave or optical frequency domain reflectometry system consists of a dc-current resulting from the local oscillator, the reflected signal, dark current in the photodiode, and current generated from background light. The current also contains the useful harmonic signal with a beat frequency corresponding to the range and radial velocity of a target. To avoid saturation and clipping due to the dc current generated in the photodiode, it is desirable to minimize the gain at dc while maintaining a high gain in the beat frequency region. We have investigated some different solutions and present a modified current-to-voltage converter using bootstrapping and added voltage gain, which addresses this problem using only one OP-amp and no dc shorting inductors.
Keywords
leukemia
Journal title
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
Serial Year
2003
Journal title
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
Record number
91712
Link To Document