Title of article
Economic viability of photovoltaic water pumping systems
Author/Authors
I. Odeh a، نويسنده , , *، نويسنده , , Y.G. Yohanis a، نويسنده , , B. Norton b، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2006
Pages
11
From page
850
To page
860
Abstract
A comparison of the economic viability of photovoltaic and diesel water pumping systems is presented for system
sizes in the range 2.8 kWp to 15 kWp. Actual performance data from installed systems are employed for the base case.
Sensitivity analysis is carried out to generalize results for other locations and conditions. The effect of system oversizing
due to mismatch of water supply and demand patterns on the economic viability of PV water pumping system is illustrated
based on real data and three-year operational experience of eight installations. Investment prospects in PV water
pumping applications for different selling price scenarios of water have been investigated.