• Title of article

    Fac¸ade solar collectors

  • Author/Authors

    Tomas Matuska *، نويسنده , , Borivoj Sourek، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2006
  • Pages
    10
  • From page
    1443
  • To page
    1452
  • Abstract
    Rational use of energy in buildings leads to a concept of active energy fac¸ades such as transparently insulated massive walls, solar thermal or PV fac¸ades, advanced glazings for daylighting purposes or double ventilated fac¸ades. The paper is concerned with the fac¸ade-integrated solar thermal collectors concept for water heating in the existing building stock in the Czech Republic (panel and brick blocks of flats), which are ready for major renovations. Thermal behavior of fac¸ade collectors compared with standard roof-located collectors in solar DHW systems was investigated. Fac¸ade solar collectors should have an area increased by approximately 30% to achieve the usual 60% solar fraction compared with conventional roof solar collectors with a 45 slope. Further increases in the solar fraction above 70% lead to a required area comparable with roof collectors but with less stagnation periods compared with roof collectors. Application of fac¸ade solar collectors affects the indoor comfort in buildings in a reasonable range. Indoor temperatures increase by no more than 1 K in all investigated configurations. Building behavior is not strongly affected by fac¸ade collectors when sufficient insulation layers are present. 2006 Elsevier Ltd. All rights reserved
  • Keywords
    Fac¸ade solar collector , Thermal integration , Solar fraction , Building retrofit
  • Journal title
    Solar Energy
  • Serial Year
    2006
  • Journal title
    Solar Energy
  • Record number