• Title of article

    Correlations for solar air heater duct with dimpled shape roughness elements on absorber plate

  • Author/Authors

    Muneesh Sethi a، نويسنده , , Varun b، نويسنده , , ?، نويسنده , , N.S. Thakur c، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2012
  • Pages
    10
  • From page
    2852
  • To page
    2861
  • Abstract
    An experimental investigation has been carried out for a range of system and operating parameters in order to analyse the effect of artificial roughness on heat transfer and friction characteristics in solar air heater duct which is having dimple shaped elements arranged in angular fashion (arc) as roughness elements on absorber plate. Duct has an aspect ratio (W/H) of 11, relative roughness pitch (p/e) range of 10–20, relative roughness height (e/Dh) range of 0.021–0.036, arc angle (a) range of 45–75 and Reynolds number (Re) ranges from 3600 to 18,000. A considerable increase in heat transfer and friction loss has been observed. The experimental data have been used to develop Nusselt number and friction factor correlations as a function of roughness parameters and operating parameters. 2012 Elsevier Ltd. All rights reserved
  • Keywords
    Dimple shaped , Heat transfer , Nusselt number , Solar air heater
  • Journal title
    Solar Energy
  • Serial Year
    2012
  • Journal title
    Solar Energy
  • Record number