Title of article
Simple diagnostic approach for determining of faulted PV modules in string based PV arrays
Author/Authors
Nuri Gokmen a، نويسنده , , Engin Karatepe، نويسنده , , ?، نويسنده , , Berk Celik a، نويسنده , , Santiago Silvestre b، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2012
Pages
14
From page
3364
To page
3377
Abstract
This paper proposes a simple diagnostic method to determine the number of open and short circuited PV modules in a string of a PV
system by taking into account the economical factor, such as minimum number of sensors. The diagnostic algorithm has as inputs the
irradiance level, the PV modules temperature, the number of PV modules present in the string analyzed and its output power. So, just
temperature and irradiance sensors, as well as a power meter by string are needed in the monitoring system forming part of the fault
diagnostic system. The proposed fault detection method has been successfully validated experimentally.
2012 Elsevier Ltd. All rights reserved.
Keywords
Supervision , Photovoltaic system , Fault diagnosis
Journal title
Solar Energy
Serial Year
2012
Journal title
Solar Energy
Record number
941169
Link To Document