Abstract
In this paper, energy separation effects in a vortex tube have been investigated using a
CFD model. A numerical simulation has been undertaken, due to the complex structure of flow. The
governing equations have been solved by the FLUENTTM code in a 2D compressible and turbulent model.
Three turbulent models, namely, RSM, Standard k-epsilon and SpalartAllmaras, have been used. The
SpalartAllmaras turbulent model, which is the first equation, was not so bad in predicting temperature
results, although the Standard k-epsilon model better predicts the results in most regions. The effects of
geometrical parameters have been investigated. The results have shown that the hot outlet size and its
shape do not affect the energy distribution in the vortex tube, and a very small diameter will decrease
the temperature separation. Different kinds of gas have been examined for the vortex tube, and it was
concluded that using helium as a refrigerant produces the largest energy separation.