Title of article
A comparative study of two synchronous Machine modeling techniques for EMTP Simulation
Author/Authors
Xu، Wilsun نويسنده , , H.W.، Dommel, نويسنده , , Cui، Yu نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
2
From page
462
To page
463
Abstract
Modeling and simulation of synchronous machines are traditionally based on the dq-axis model. An alternative method that uses direct phase-domain representation has been proposed over the past 30 years. One of the recent contributions , which is published as a letter in the June 2001 edition of Power Engineering Review , claims that the dq-axis model will give erroneous results in some cases, while the phase-domain model does not have such problems. This is a very bold claim. The purpose of this letter is to verify the conclusions of that Letter. Our simulation results indicate that both modeling methods produce very similar results. The letterʹs conclusion might have resulted from a misuse of the PSCAD/EMTDC software.
Keywords
Hydrograph
Journal title
IEEE Transactions on Energy Conversion
Serial Year
2004
Journal title
IEEE Transactions on Energy Conversion
Record number
98577