• Title of article

    Measurements of endotoxin on ambient loaded PM filters after long-term storage

  • Author/Authors

    Verena Morgenstern، نويسنده , , b، نويسنده , , Wolfgang Bischof، نويسنده , , Andrea Koch، نويسنده , , Joachim Heinrich and for the LISAplus study group، نويسنده , , ?، نويسنده ,

  • Issue Information
    هفته نامه با شماره پیاپی سال 2006
  • Pages
    6
  • From page
    574
  • To page
    579
  • Abstract
    At present there exist unsolved questions, whether endotoxin measurements on PM filters show valid measurements after longterm storage of loaded PM filters. As part of the TRAPCA study we collected particles with a 50% aerodynamic cut-off diameter of 2.5 μm (PM2.5) at 40 outdoor sites and particles less than 10 μm in size (PM10) at a subset of these sites (N=12) in Munich. The PM filters were cut in halves and endotoxin was measured in the extract of one filter half 2–3 years after PM collection. Here we present the results of repeated endotoxin measurements, where the association between previously measured endotoxin concentrations, measurements from stored eluates, and measurements in extracts of the second filter halves were determined. No statistically significant changes were seen between our old measurements and those from the stored eluates. Additionally, no change was observed between previously measured endotoxin concentrations and those from the stored set of filter halves. We found an average increase of 5% between our old measurements and those from the stored eluates and of 19% between the old measurements and those from the stored set of filter halves. The correlations between the previously measured endotoxin concentrations and the repeated measurements from the stored eluates were high (r=0.789) for EU/m3 PM2.5. Since endotoxin was evaluated from the same set of filter halves, it is obvious that storage over three years did not substantially effect the correlation of the endotoxin content. Regarding the outliers from previous measurements unsymmetric endotoxin spots on one out of 48 filter halves could be determined. Apart from this we conclude that the endotoxin is homogenously distributed on the filter halves and that endotoxin levels, which were repeatedly measured from filters stored over three years, could be determined validly.
  • Keywords
    Storage of PM-filters , Endotoxin , outdoor , Bacteria , particulate matter
  • Journal title
    Science of the Total Environment
  • Serial Year
    2006
  • Journal title
    Science of the Total Environment
  • Record number

    986014