• Title of article

    UV intensity measurement for a novel 222 nm excimer lamp using chemical actinometer

  • Author/Authors

    J.-Y. Zhang، نويسنده , , I.W Boyd، نويسنده , , H. Esrom، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    5
  • From page
    482
  • To page
    486
  • Abstract
    Photohydrate of uridine in neutral aqueous solution is used for the determination of the ultraviolet (UV) intensity of a novel excimer lamp, employing a dielectric barrier discharge in krypton chloride to provide intense narrow band radiation at λ=222 nm (KrCl*). The intensity measurement is based on UV spectral absorption data. A photokinetic model is presented for the reaction which is generally applicable for any photochemical system. The electrical power dependence of the UV intensity generated as well as the efficiency of the lamps was investigated.
  • Journal title
    Applied Surface Science
  • Serial Year
    1997
  • Journal title
    Applied Surface Science
  • Record number

    991412