شماره ركورد
15494
عنوان به زبان ديگر
STUDY OF ELECTROCHEMICAL CHLORIDE EXTRACTION AS A NON-DESTRUCTIVE REPAIR METHOD: PART 2. STRUCTURAL ELEMENT TEST SAMPLE.
پديد آورندگان
Hosseini A. نويسنده , Khaloo Ali R. نويسنده
از صفحه
247
تا صفحه
255
تعداد صفحه
9
چكيده لاتين
This paper is the second part of the paper that provides information on representative parameters in electro-chemical chloride extraction. In part one, results of discrete test samples were outlined. A structural element in the form of Reinforced Concrete (RC) slab was constructed and tested to evaluate the ECE performance in a simulated structure. The representative parameters of ECE were determined experimentally. The experimental program investigates chloride and alkali concentration, chloride removal efficiency, transference number and half-cell potential. Test results on RC slab are compatible with those obtained in the Part one of the study on discrete test samples; thereby confirm the capability of applying the method to real structures.
شماره مدرك
1199193
لينک به اين مدرک