• شماره ركورد
    21994
  • عنوان به زبان ديگر
    Comparison of extracted teeth and simulated resin blocks on apical canal transportation.
  • پديد آورندگان

    Khalilak Zohreh نويسنده , Fallahdoost Arjang نويسنده , Dadresanfar Bahareh نويسنده , Rezvani Gholamreza نويسنده

  • از صفحه
    109
  • تا صفحه
    112
  • تعداد صفحه
    4
  • چكيده لاتين
    Introduction: We aimed to compare apical canal transportation of extracted teeth and two types of simulated resin blocks. Materials and Methods: Mesiobuccal root of extracted maxillary molars, high hardness simulated resin blocks (Knoop hardness=40) and low hardness simulated resin blocks (Knoop hardness=22) were prepared with K-files using step-back technique (n=15 canals in each group). Double exposure radiographic technique was used for extracted teeth. Simulated resin blocks were stabilized and scanned before and after preparation. Pre and post-preparation pictures were superimposed and apical transportation was measured. The data were analyzed statistically using ANOVA and Tukey HSD tests. Results: There was no significant difference in apical canal transportation between extracted teeth and high hardness resin blocks (P>0.05). Low hardness resin blocks showed more apical transportation than the other groups (P<0.05). Conclusion: Under the conditions of this study, apical canal transportation for extracted teeth and high hardness simulated resin blocks were similar.
  • شماره مدرك