چكيده فارسي
The cement industry is one of the primary producers of carbon dioxide, which is a major greenhouse gases. Electrostatic precipitators (ESPs) are common installations on coal-fired cement plants to remove over 99% of ash particles, typical efficiency of ESP as a function of geometrical and operation factors. In this paper investigation revealed a simple model, developing the Deutsch collection theory .The model evaluate the collection efficiency of ESP in cement plants depends on two operations factors, applied voltage and current density. The effects of the gap between collection-plates and discharge-wires on collection efficiency were studied.