شماره ركورد كنفرانس
3338
عنوان مقاله
Downstream Water Cooler, an Economical Choice over Destructive Burner: A Case Study of Shiraz Refinery
پديدآورندگان
Shamseddini Arash Department of Process Engineering - Shiraz Oil Refining Co , Yazdan Panah Majid Department of Process Engineering - Shiraz Oil Refining Co , Oudbor Masoud Department of Process Engineering - Shiraz Oil Refining Co
كليدواژه
Water Carry-Over , Water Cooler , Sour Water Treating plant , Sulfur Recovery unit , Slops , Computer Simulation
سال انتشار
ارديبهشت 1392
عنوان كنفرانس
نخستين همايش ملي مهندسي فرآيند
زبان مدرك
انگليسي
چكيده لاتين
In the coming pages the design of a water cooler is investigated in order to reduce the water
carry-over from the waste gas stream of the Sour Water Treating plant. High water content
prevents the gas to be burned inside the incinerator of the Sulfur Recovery unit and is
unwillingly sent to the flare network resulting into corrosion issues and Slops formation.
Upon simulating the whole water treating unit via Aspen v. 2006.5 to obtain operating data
for the gas stream, using HTRI v. 5.0 a highly efficient water cooler is designed which
practically condenses over 53 percent of water from the vapor phase making it suitable for
introduction to the incinerator.