شماره ركورد كنفرانس
3976
عنوان مقاله
Application of orthogonal pixel correction for MIA-QSAR study of anilinquinolines
پديدآورندگان
Mazrabidi Solmaz Islamic Azad University, Arak , Niazi Ali ali.niazi@gmail.com Islamic Azad University, Tehran , Yazdanipour Atisa Islamic Azad University, Arak
تعداد صفحه
1
كليدواژه
QSAR , Anilinquinolines , Image analysis , PLS , OSC , PLS
سال انتشار
1396
عنوان كنفرانس
ششمين سمينار ملي دوسالانه كمومتريكس ايران
زبان مدرك
انگليسي
چكيده فارسي
The aim of this study was to investigate, for the first time, the possibility of using orthogonal signal
(pixel) correction (OPC) and multivariate calibration methods for QSAR study of anilinquinolines [1] by
image analysis. The results obtained, with and without using OPC algorithm as a preprocessing treatment
of original data, were compared. The aim of this work is to propose OPC and PLS (OPC-PLS) method to
modeling in QSAR study. To our knowledge this is the first report on the QSAR study. In the MIA-QSAR
[2, 3] method, the descriptors are the pixels of images that can be two or three dimensional.
These pixels are correlated with dependent variables for making QSAR models [4]. Each image of
dimension 120×150 pixels was unfolded to a 1×18000 row and then the 62 images were grouped to form
a 62×18000 matrix. Columns with zero variance were removed to minimize memory, reducing the size of
matrix to 62×1405. The resulted model showed high prediction ability with RMSEP of 0.0106 for
OSC-PLS.
كشور
ايران
لينک به اين مدرک