شماره ركورد كنفرانس
4567
عنوان مقاله
The Study of Performance Comparison of Flat Plate and Evacuated Tube Collectors for Domestic Hot Water Heating Systems in Kerman
Author/Authors
Hadi Farzan Mechanical Engineering Department - Higher Educational Complex of Bam, 76615-314, Bam, Iran
كليدواژه
Plat plate collector , Evacuated tube collector , Energy performance analysis , Economic analysis , Solar water heater , Solar fraction
سال انتشار
اسفند 1397
عنوان كنفرانس
ششمين كنفرانس ملي ساليانه انرژي پاك
زبان مدرك
لاتين
چكيده لاتين
This study represents a year round energy performance of two solar water heater
(SWH) systems with 4m2 flat plate collector (FPC) and evacuated tube collector
(ETC) operating under the same weather conditions. The energy performance of the
two considered systems was compared on monthly and yearly basis. The obtained
results showed that for an annual total solar insolation of 2 2056kWhm , the total of
1 3577kWhy and 1 4201kWhy heat energy were collected by 4m2 FPC and ETC
systems, respectively. The annual average efficiency by FPC system was 43%, while
its annual solar fraction was 50%. The ETC system had 51% efficiency with 58%
solar fraction. The economic analysis showed that both solar water heating system
are not economically viable under prevailing costs in Iran. Furthermore, according
to the obtained results the FPCs are more favorable than the ETCs due to its
economic analysis and energy performance. These results provide useful information
for households and policy makers.
كشور
ايران
تعداد صفحه 2
7
از صفحه
1
تا صفحه
7
لينک به اين مدرک