شماره ركورد كنفرانس
5048
عنوان مقاله
Prediction of Mean drop Size in Pulsed Packed Extraction Columns
Author/Authors
Meisam ،Torab-Mostaedi , Jaber ،Safdari , Farzad ،Torabi-Hokmabadi School of Chemical Engineering - University College of Engineering - University of Tehran - Tehran, Iran
كليدواژه
Pulsed Packed Column , Sauter Mean Diameter , drop Size , Holdup
سال انتشار
1388
عنوان كنفرانس
ششمين كنگره بين المللي مهندسي شيمي
زبان مدرك
انگليسي
چكيده فارسي
فاقد چكيده
چكيده لاتين
In the present work, Sauter mean drop sizes have been measured in a pulsed packed extraction column for two liquid
systems. The effects of pulsation intensity, phase flow rates, and interfacial tension on drop size have been investigated
under a variety of operating conditions. The drop size is influenced mainly by pulsation intensity and interfacial tension.
Significant, but weaker, are the effects of continuous and dispersed phase flow rates. A precise correlation is proposed
for predicting mean drop size in terms of operating variables and physical properties of the liquid systems. Good
agreement between prediction and experiments is found for all operating conditions that were investigated.
كشور
ايران
تعداد صفحه 2
8
از صفحه
1
تا صفحه
8
لينک به اين مدرک