شماره ركورد كنفرانس
5048
عنوان مقاله
Modification of finger type transfer line exchangers for resolving the problem of corrosion and failure in hot tube sheet section
Author/Authors
H ،Farahani Arak Petrochemical Company، Iran
كليدواژه
TLE , Transfer Line Exchanger , Modification , Water Tube Boiler
سال انتشار
1388
عنوان كنفرانس
ششمين كنگره بين المللي مهندسي شيمي
زبان مدرك
انگليسي
چكيده فارسي
فاقد چكيده
چكيده لاتين
As we know the transfer line exchangers are widely used in olefin plants for quenching of cracked gases outlet
from furnaces and is used to prevent the formation of unwanted materials that may decrease the efficiency of olefin
productions. The other benefit of this process is the generation of high high pressure steam. The main specification of
this exchangers is a considerable high temperature of cracked gas inlet to TLE that enforce a high heat flux to hot tube
sheet especially at center and cause the problem of corrosion and ultimately failure of tube sheet. In this paper three
different types of TLEs compared to each other and with considering the Natural circulation water tube boiler
calculations results for finger type TLE, several modifications proposed to improve the problem of failure in hot tube
sheet section for this type of TLE.
كشور
ايران
تعداد صفحه 2
7
از صفحه
1
تا صفحه
7
لينک به اين مدرک