• Author/Authors

    köle, m. murat çankırı karatekin üniversitesi - edebiyat fakültesi - coğrafya bölümü, Turkey

  • Title Of Article

    Minimum Water Flow Assessment for Downstream of Boğazköy Dam and HEPP: Tennant and Flow Duration Methods

  • شماره ركورد
    43620
  • Abstract
    Nowadays, determination of minimum water flow from dams that are build on rivers, has a vital importance in order to utilize water resources effectively and efficiently. In this study, minimum water flow for Boğazköy Dam and HEPP is calculated based on two different hydrologic methods, namely flow duration curve and Tennant (1976) methods and they are compared with each other. As a result of current study, based on Tennant method, for raid periods minimum 1,34 m³/sec and for wet periods minimum 1,69 m³/sec water flow is calculated. Based on flow duration method Q70 and Q95 are calculated respectively 6,59 m3/sec and 2,47 m³/sec. Between selected methods, it is more convenient to use the Q70 for the environmental flow.
  • From Page
    326
  • NaturalLanguageKeyword
    Boğazköy Dam and HEPP , hydrological methods , environmental flow , river base
  • JournalTitle
    International Journal of Geography and Geography Education
  • To Page
    338
  • JournalTitle
    International Journal of Geography and Geography Education