• DocumentCode
    1007817
  • Title

    Analysis and design of a robust average current mode control loop for parallel buck DC-DC converters to reduce line and load disturbance

  • Author

    Garcerá, G. ; Figueres, E. ; Pascual, M. ; Benavent, J.M.

  • Author_Institution
    Dept. de Ingenieria Electron., Univ. Politecnica de Valencia, Spain
  • Volume
    151
  • Issue
    4
  • fYear
    2004
  • fDate
    7/7/2004 12:00:00 AM
  • Firstpage
    414
  • Lastpage
    424
  • Abstract
    A robust control scheme for multi-module parallel buck DC-DC converters with average current mode control (ACC) is presented. The proposed loop adds an inner loop to the conventional current and voltage ACC loops, reducing the sensitivity of the outer voltage loop to the changing power stage parameters: number of modules, input voltage, load and component tolerances. The loop improves significantly the disturbance rejection of the converter, i.e. the closed loop output impedance and audiosusceptibility, while preserving the stability and the loop gain crossover frequency to a significant extent. The performance of the proposed scheme is demonstrated by both small-signal and large signal experimental results.
  • Keywords
    DC-DC power convertors; electric current control; robust control; current mode control loop; loop gain crossover frequency; parallel buck DC-DC converters; robust control;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-2352
  • Type

    jour

  • DOI
    10.1049/ip-epa:20040319
  • Filename
    1305510