DocumentCode
1007817
Title
Analysis and design of a robust average current mode control loop for parallel buck DC-DC converters to reduce line and load disturbance
Author
Garcerá, G. ; Figueres, E. ; Pascual, M. ; Benavent, J.M.
Author_Institution
Dept. de Ingenieria Electron., Univ. Politecnica de Valencia, Spain
Volume
151
Issue
4
fYear
2004
fDate
7/7/2004 12:00:00 AM
Firstpage
414
Lastpage
424
Abstract
A robust control scheme for multi-module parallel buck DC-DC converters with average current mode control (ACC) is presented. The proposed loop adds an inner loop to the conventional current and voltage ACC loops, reducing the sensitivity of the outer voltage loop to the changing power stage parameters: number of modules, input voltage, load and component tolerances. The loop improves significantly the disturbance rejection of the converter, i.e. the closed loop output impedance and audiosusceptibility, while preserving the stability and the loop gain crossover frequency to a significant extent. The performance of the proposed scheme is demonstrated by both small-signal and large signal experimental results.
Keywords
DC-DC power convertors; electric current control; robust control; current mode control loop; loop gain crossover frequency; parallel buck DC-DC converters; robust control;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings -
Publisher
iet
ISSN
1350-2352
Type
jour
DOI
10.1049/ip-epa:20040319