• DocumentCode
    1016677
  • Title

    The Anomalous Behavior of the Moving Systems of Single-Phase A-C Watt-Hour Meters at No Load

  • Author

    Holtz, F.C.

  • Author_Institution
    Vice-President and chief engineer of the Sangamo Electric Company, Springfield, Ill.
  • Volume
    59
  • Issue
    2
  • fYear
    1940
  • Firstpage
    116
  • Lastpage
    123
  • Abstract
    Investigation reveals the moving systems of induction watt-hour meters to be in a peculiar state of motion under the condition of potential excitation only. The present paper offers a simple explanation for its origin and provides a method for recording and determining the actual value of the motion in various parts of the moving system. Interesting conclusions may be drawn from the investigation which throw much light on the problem of meter-bearing performance.
  • Keywords
    Acceleration; Circuits; Dielectrics; Electric shock; Gases; Leg; Petroleum; Testing; Voltage; Water;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1940.5058107
  • Filename
    5058107