DocumentCode
1016677
Title
The Anomalous Behavior of the Moving Systems of Single-Phase A-C Watt-Hour Meters at No Load
Author
Holtz, F.C.
Author_Institution
Vice-President and chief engineer of the Sangamo Electric Company, Springfield, Ill.
Volume
59
Issue
2
fYear
1940
Firstpage
116
Lastpage
123
Abstract
Investigation reveals the moving systems of induction watt-hour meters to be in a peculiar state of motion under the condition of potential excitation only. The present paper offers a simple explanation for its origin and provides a method for recording and determining the actual value of the motion in various parts of the moving system. Interesting conclusions may be drawn from the investigation which throw much light on the problem of meter-bearing performance.
Keywords
Acceleration; Circuits; Dielectrics; Electric shock; Gases; Leg; Petroleum; Testing; Voltage; Water;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Transactions of the
Publisher
ieee
ISSN
0096-3860
Type
jour
DOI
10.1109/T-AIEE.1940.5058107
Filename
5058107
Link To Document