DocumentCode
1016874
Title
Some high-power window failures
Author
Vaughan, J.R.M.
Author_Institution
General Electric Co., Schenectady, N. Y.
Volume
8
Issue
4
fYear
1961
fDate
7/1/1961 12:00:00 AM
Firstpage
302
Lastpage
308
Abstract
Two types of RF window failure in a high-power magnetron are investigated. Cracking is shown to depend on electrostatic charging of an evaporated metallic deposit on the window. Punctures were investigated by observation of X-ray stereo-autograms, and are shown to result from an internal multipactor discharge, which in turn is enabled to function at high voltages by the stray magnetic field. Methods for curing both types of defect are given, with evidence that they are successful. The methods are applicable to other high-power microwave tubes, both magnetrons and klystrons.
Keywords
Ash; Cathodes; Ceramics; Electrostatics; Helium; High power amplifiers; Impedance; Klystrons; Machining; Magnetic fields; Narrowband; Oscillators; Passband; Powders; Radio frequency; Senior members; Sparks; Voltage;
fLanguage
English
Journal_Title
Electron Devices, IRE Transactions on
Publisher
ieee
ISSN
0096-2430
Type
jour
DOI
10.1109/T-ED.1961.14804
Filename
1472967
Link To Document