• DocumentCode
    1017593
  • Title

    Relative Accuracy of Three-Phase Metering Combinations

  • Author

    Weller, C.T.

  • Author_Institution
    Electrical engineer in the general engineering laboratory of the General Electric Company, Schenectady, N. Y.
  • Volume
    60
  • Issue
    10
  • fYear
    1941
  • Firstpage
    925
  • Lastpage
    929
  • Abstract
    This paper grades several three-phase combinations of instrument transformers and watthour meters under various conditions according to their approach to the best standard practice. The combinations are described and sources of uncertainty or of error are discussed. Diagrams are included to show the schematic connections of the component transformers and meters, both separately and in combination and of the power systems to be metered.
  • Keywords
    Cellular neural networks; Current transformers; Instrument transformers; Law; Power system harmonics; Power systems; Power transformers; Voltage transformers; Watthour meters; Wattmeters;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1941.5058203
  • Filename
    5058203