  • Abstract
    Motor protectors are selected and applied so that they restrict the motor winding temperature to specified values at normal voltage and frequency and a room temperature of 40°C. The accompanying table shows the probable increase (or decrease) in winding temperatures which may occur on account of abnormal voltages, frequencies, or ambient temperatures, or with restricted ventilation.
  • Keywords
    Coils; Fuses; Manufacturing; Protection; Protective relaying; Resistors; Strips; Switches; Temperature dependence; Thermal resistance;