DocumentCode
1022819
Title
Magnetoelastic amorphous metal fluxgate magnetometer
Author
Mermelstein, M.D.
Author_Institution
Geo-Centers, Inc., Newton Center, USA
Volume
22
Issue
10
fYear
1986
Firstpage
525
Lastpage
526
Abstract
A fluxgate magnetometer is presented which exploits the magnetic field dependence to the stress-driven magnetisation fluctuations in magnetostrictive metallic glass ribbons. A magnetometer constructed with an unannealed ribbon, a piezoelectric ceramic driving element and a 100-turn pick-up coil exhibits a minimum detectable magnetic field of 15 nT/¿Hz in the DC to 1 Hz bandwidth.
Keywords
magnetic field measurement; magnetoelastic effects; magnetometers; fluxgate magnetometer; magnetic field dependence; magnetostrictive metallic glass ribbons; minimum detectable magnetic field; pick-up coil; piezoelectric ceramic driving element; stress-driven magnetisation fluctuations;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19860358