Electric field probes--A review
Author
Bassen, Howard I. ; Smith, Glenn S.
Author_Institution
Dept. of Health and Human Services, Nat´´l. Center for Devices and Radiological Health, Rockville, MD USA
Volume
31
Issue
5
fYear
1983
fDate
9/1/1983 12:00:00 AM
Firstpage
710
Lastpage
718
Abstract
Electric field probes consisting of a dipole antenna, RF detector, nonperturbing transmission line, and readout device have been implemented in a variety of ways. Three orthogonal dipoles are generally used in an
-field probe to provide a response which is nearly isotropic for all polarizations of the incident field. Diode detectors have been used with electrically short or resistivity loaded dipoles to produce very broadband devices (0.2 MHz to 26 GHz). Thermocouple detectors are used to provide true time-averaged data for high peak-power modulated fields. Optical fibers, together with a suitably modulated light source, may be used to form a wide-band nonperturbing data link from the dipole and detector to a remote readout. Application of
-field probes range from the measurement of fields in living animals exposed to nonionizing radiation to the measurement of fields in air for electromagnetic compatability or radiation safety purposes. Probes are available that can measure field strengths from less than 1 V/m to over 1000 V/m (rms).
-field probe to provide a response which is nearly isotropic for all polarizations of the incident field. Diode detectors have been used with electrically short or resistivity loaded dipoles to produce very broadband devices (0.2 MHz to 26 GHz). Thermocouple detectors are used to provide true time-averaged data for high peak-power modulated fields. Optical fibers, together with a suitably modulated light source, may be used to form a wide-band nonperturbing data link from the dipole and detector to a remote readout. Application of
-field probes range from the measurement of fields in living animals exposed to nonionizing radiation to the measurement of fields in air for electromagnetic compatability or radiation safety purposes. Probes are available that can measure field strengths from less than 1 V/m to over 1000 V/m (rms).Keywords
Probe antennas; Conductivity; Dipole antennas; Electromagnetic measurements; Electromagnetic radiation; Envelope detectors; Optical fiber polarization; Optical fibers; Probes; Radio frequency; Transmission line antennas;