• DocumentCode
    1038416
  • Title

    Electron mobility in argon and carbon dioxide

  • Author

    Kucerovsky, Z.

  • Author_Institution
    Fac. of Eng. Sci., Univ. of Western Ontario, London, Ont.
  • Volume
    42
  • Issue
    4
  • fYear
    2006
  • Firstpage
    900
  • Lastpage
    908
  • Abstract
    Electron drift velocities were determined in argon and in mixtures of argon with carbon dioxide, using media processed to yield a high degree of purity. The measurements were performed at a pressure of 760 torr and a temperature of 25degC. The medium was confined in a cylindrical measuring chamber made of polytetrafluorethylene (10-mm diameter, 10-mm length). The electrodes used to generate electric field were circular, made of stainless steel, and vacuum coated with gold. A layer of ionized gas (approximately 4 mm thick) was created near the negative electrode with a 10-mCi tritium radioactive source. The cell was connected to a pulse generator with a low duty factor, which ensured that most of the time the medium was in the quiescent state. During the active state, an axial electric field was created in the chamber by a short negative pulse applied to the cathode. To assure purity and to facilitate the transport of calibration samples, the gaseous medium was flown from anode to cathode via the chamber (50 mlmiddotmin-1 ). The layer of plasma near the cathode was electrically neutral most of the time since the electrodes were effectively grounded during the quiescent state. The pulsed electric field separated the charge carriers in the plasma layer into fast electronic and slow ionic charges. The time-amplitude dependence reflected the charge separation dynamics and was used for the determination of drift velocities. The velocity data were measured in ultrahigh-purity argon and in binary mixtures of argon with carbon dioxide (from 1.0%v to 6.5%v). In argon, for field intensities Eisin(0,8) kVmiddotm-1, the velocity range was veisin(0,2.8) kmmiddots-1, and for Eisin(8,35) Vmiddotm-1, veisin(0,2.8) kmmiddots-1. In mixtures of Ar-CO2, electron drift velocity depended on the concentration: For field E=8 kVmiddotm -1, veisin(7,18) kmmiddots- - -1, and for E=35 kVmiddotm-1, veisin(12,24) kmmiddots-1. The data obtained in this study can be used for the determination of the voltage-current characteristics and other parameters of corona discharges. The data are of interest to those who study the physical phenomena in dc and pulsed corona discharges
  • Keywords
    anodes; argon; carbon compounds; cathodes; corona; electric fields; electron mobility; gas mixtures; polymers; 10 mm; 25 degC; 760 torr; Ar; CO2; anode; cathode; charge separation dynamics; corona discharges; cylindrical measuring chamber; electric fields; electrodes; electron drift velocities; electron mobility; electronic charge; field intensity; ionic charge; polytetrafluorethylene; pulse generator; Argon; Carbon dioxide; Cathodes; Corona; Electrodes; Electron mobility; Performance evaluation; Plasma measurements; Plasma temperature; Pressure measurement; Argon; argon–carbon dioxide; electron drift velocity; gas composition; mobility; pulse methods;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2006.877734
  • Filename
    1658318