  • Title

    Study of Integral Water Cooling System for 154 kV Self Contained Oil Filled Cables

  • Author

    Yamamoto, T. ; Kurihara, H. ; Yokose, K. ; Nishino, I. ; Furukawa, K.

  • Author_Institution
    The Kansai Electric Power Co., Inc.
  • Issue
    6
  • fYear
    1973
  • Firstpage
    1999
  • Lastpage
    2006
  • Abstract
    This paper deals with the problems of an integral water cooled cable system to increase the capability of 154 kV underground transmission line. The trial line equivalent to a commercial one was constructed to investigate the cooling effect of cable and joints, the suppression of thermal expansion and so on. We found that the transmission of 500 MVA/cct of 154 kV 2000 mm2 aluminum sheathed oil filled cable is possible using it. Descriptions are given of these results.
  • Keywords
    Aluminum; Conductors; Cooling; Oil filled cables; Power cables; Power transmission lines; Substations; Temperature; Testing; Thermal expansion;