• DocumentCode
    1052867
  • Title

    Class IE Cables for Nuclear Power Generating Stations

  • Author

    McIlveen, E.E. ; Garrison, V.L. ; Dobrowolski, G.T.

  • Author_Institution
    The Okonite Company
  • Issue
    4
  • fYear
    1974
  • fDate
    7/1/1974 12:00:00 AM
  • Firstpage
    1121
  • Lastpage
    1132
  • Abstract
    With the publication of IEEE Guide P 383 For Qualification Testing, it is appropriate to present typical data relating-to this document, and to briefly discuss its significance. Designed life performance for nuclear stations must be predicated for the most part on test data obtained from cable systems under simulated environmental conditions which are peculiar to this application. This paper presents data in the areas of (1) long time exposure to moisture at elevated temperature, (2) air oven heat aging, (3) simulated reactor radiation during normal operation as well as during and after a design basis event, and (4) flame testing of cables.
  • Keywords
    Aging; Cables; Life testing; Moisture; Nuclear power generation; Ovens; Power generation; Qualifications; System testing; Temperature;