DocumentCode
1063124
Title
Performance of synchronous machines operating with unbalanced armature windings
Author
Rhudy, R.G. ; Snively, H.D. ; White, J.C.
Author_Institution
Power Technol. Inc., Schenectady, NY, USA
Volume
3
Issue
2
fYear
1988
fDate
6/1/1988 12:00:00 AM
Firstpage
391
Lastpage
397
Abstract
The performance of synchronous machines operating with armature windings unbalanced by having coils cut out following winding failure is considered. The resulting unbalanced voltages and currents tend to produce overheating and may produce magnetic pull-over or excessive vibration. A method of calculating winding currents and voltages in unbalanced windings is presented. The conditions for winding modification schemes to control magnetic pull-over and severe vibration are discussed. This analysis is also applicable to polyphase induction motors
Keywords
machine windings; synchronous machines; magnetic pull-over; overheating; polyphase induction motors; synchronous machines; unbalanced armature windings; vibration; winding currents; winding failure; winding voltages; Circuits; Coils; DH-HEMTs; Induction generators; Induction motors; Machine windings; Stator windings; Synchronous machines; Vibrations; Voltage;
fLanguage
English
Journal_Title
Energy Conversion, IEEE Transactions on
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/60.4746