• DocumentCode
    1063124
  • Title

    Performance of synchronous machines operating with unbalanced armature windings

  • Author

    Rhudy, R.G. ; Snively, H.D. ; White, J.C.

  • Author_Institution
    Power Technol. Inc., Schenectady, NY, USA
  • Volume
    3
  • Issue
    2
  • fYear
    1988
  • fDate
    6/1/1988 12:00:00 AM
  • Firstpage
    391
  • Lastpage
    397
  • Abstract
    The performance of synchronous machines operating with armature windings unbalanced by having coils cut out following winding failure is considered. The resulting unbalanced voltages and currents tend to produce overheating and may produce magnetic pull-over or excessive vibration. A method of calculating winding currents and voltages in unbalanced windings is presented. The conditions for winding modification schemes to control magnetic pull-over and severe vibration are discussed. This analysis is also applicable to polyphase induction motors
  • Keywords
    machine windings; synchronous machines; magnetic pull-over; overheating; polyphase induction motors; synchronous machines; unbalanced armature windings; vibration; winding currents; winding failure; winding voltages; Circuits; Coils; DH-HEMTs; Induction generators; Induction motors; Machine windings; Stator windings; Synchronous machines; Vibrations; Voltage;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/60.4746
  • Filename
    4746