• DocumentCode
    1065326
  • Title

    Off-resonance transformer charging for 250-kV water blumlein

  • Author

    Cook, Edward G. ; Reginato, Louis L.

  • Author_Institution
    University of California, Livermore, CA
  • Volume
    26
  • Issue
    10
  • fYear
    1979
  • fDate
    10/1/1979 12:00:00 AM
  • Firstpage
    1512
  • Lastpage
    1517
  • Abstract
    An off-resonance transformer for charging a 250-kV Blumlein system provides a viable alternative to other charging schemes by permitting the use of conventional thyratrons. Such a transformer must have reliability, a reasonable voltage stepup, and a nonreversing primary current. This paper presents the analysis, design, and performance data for such a transformer. The strong interrelationship between transformer design and Blumlein requirements necessitates that Blumlein description and design criterion be briefly presented prior to transformer design such that transformer load requirements be defined.
  • Keywords
    Acceleration; Breakdown voltage; Coaxial cables; Electric breakdown; Electron beams; Oil insulation; Safety; Surface charging; Switches; Thyratrons;
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9383
  • Type

    jour

  • DOI
    10.1109/T-ED.1979.19640
  • Filename
    1480218