DocumentCode
1072058
Title
Some Considerations on AC Water Trees in Crosslinked Polyethylene
Author
Yoshimitsu, T. ; Mitsui, H. ; Kenjo, S. ; Nakakita, T.
Author_Institution
Toshiba Corporation Tsurumi-ku, Yokahama, Japan
Issue
1
fYear
1983
Firstpage
23
Lastpage
27
Abstract
This paper first confirms that moisture absorption of XLPE (crosslinked polyethylene) obeys Fick´s law. The effects of moisture absorption and temperature on water treeing in XLPE are then discussed. The results of physical and chemical tests of the sites of water trees are presented. Infrared Fourier Transform Spectro-scopy (FT-IR) test results show the chemical aspects of the deterioration. Finally, the authors suggest that the water tree is due to a shift in chemical equilibrium (free energy) of the insulating materials due to the impressed electric field.
Keywords
Chemicals; Dielectrics and electrical insulation; Electromagnetic wave absorption; Fourier transforms; Infrared spectra; Moisture; Polyethylene; Temperature; Testing; Trees - insulation;
fLanguage
English
Journal_Title
Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
0018-9367
Type
jour
DOI
10.1109/TEI.1983.298578
Filename