Abstract
One of the main factors limiting the reliability of metallized polypropylene capacitors is degradation of the electrode/sprayed end contacts, a process known to be caused by thermal effects and the effects of electrical discharges. It has also been suggested that electrodynamic effects could contribute to the phenomenon; an experiment was performed to investigate the possibility and the findings confirm that this is indeed the case.
Keywords
capacitors; measurement by laser beam; metallisation; polymers; reliability; vibration measurement; current pulses; electrical discharges; electrode/sprayed end contacts degradation; electrodynamic effects; laser vibrometry; metallized polypropylene capacitors; reliability; small diametral vibrations measurements; thermal effects; Capacitors; Contacts; Current measurement; Electrodes; Metallization; Optical pulses; Pulse measurements; Thermal degradation; Thermal spraying; Vibration measurement;