• DocumentCode
    1073694
  • Title

    Measurements of small diametral vibrations in metallized polypropylene capacitors subjected to current pulses, by means of laser vibrometry

  • Author

    Pirani, Stefano ; Rinaldi, Paola

  • Author_Institution
    Dipt. di Ingegneria Elettrica, Univ. of Bologna, Italy
  • Volume
    18
  • Issue
    1
  • fYear
    2003
  • fDate
    1/1/2003 12:00:00 AM
  • Firstpage
    277
  • Lastpage
    282
  • Abstract
    One of the main factors limiting the reliability of metallized polypropylene capacitors is degradation of the electrode/sprayed end contacts, a process known to be caused by thermal effects and the effects of electrical discharges. It has also been suggested that electrodynamic effects could contribute to the phenomenon; an experiment was performed to investigate the possibility and the findings confirm that this is indeed the case.
  • Keywords
    capacitors; measurement by laser beam; metallisation; polymers; reliability; vibration measurement; current pulses; electrical discharges; electrode/sprayed end contacts degradation; electrodynamic effects; laser vibrometry; metallized polypropylene capacitors; reliability; small diametral vibrations measurements; thermal effects; Capacitors; Contacts; Current measurement; Electrodes; Metallization; Optical pulses; Pulse measurements; Thermal degradation; Thermal spraying; Vibration measurement;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/TPWRD.2002.804008
  • Filename
    1159931