DocumentCode
1073877
Title
Equipment for the Energy Measurement of Partial Discharges
Author
Garcia, G. ; Fallou, B.
Author_Institution
Laboratoire central des Industries Electriques Fontenay-auz-Roses France
Issue
3
fYear
1984
fDate
6/1/1984 12:00:00 AM
Firstpage
223
Lastpage
226
Abstract
Unlike apparent charge, energy is an inherent characteristic of partial discharge (DP) and may be used as an objective criterion for their evaluation. Since energy dissipation is responsible for the damaging effect of discharges, the amount of energy liberated in a PD situation is a suitable estimation of the involved risks. Discharge energy measurement was accomplished using a special and readily made metering circuit, including a correlator unit. Good correlations were found to exist between discharge energy and insulation degradation in simple liquid or solid insulating models.
Keywords
Cathode ray tubes; Correlators; Degradation; Dielectrics and electrical insulation; Electrostatics; Energy measurement; Fault location; Partial discharges; Testing; Voltage;
fLanguage
English
Journal_Title
Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
0018-9367
Type
jour
DOI
10.1109/TEI.1984.298752
Filename
4081235
Link To Document