• DocumentCode
    1078639
  • Title

    Frequency measurement system for gyrotron diagnostics

  • Author

    Prinz, Hansjwöerg Oliver

  • Volume
    26
  • Issue
    4
  • fYear
    2007
  • Firstpage
    25
  • Lastpage
    30
  • Abstract
    A highly cost-efficient frequency measurement svstem for frequency diagnostics of high-power gyrotrons in the frequency range of 100-175 GHz has been developed. The advantages of this system are a wide bandwidth of 75 GHz, and the typical sensitivity of -30 dBm. This new measurement system can measure the frequency with an accuracy of better than 10 kHz in real time. It is easy to observe frequency drifts and oscillating modes of gyrotrons. With the PC-based control of the system, the operation is very easy. The compact system replaces the previous system and will be used for future diagnostics on gyrotrons.
  • Keywords
    frequency measurement; gyrotrons; time-frequency analysis; PC-based control; bandwidth 75 GHz; broadband real-time system; filterbank spectometer; frequency 100 GHz to 175 GHz; frequency measurement system; frequency time analysis; frequency time-analysis; gyrotron diagnostics; megawatt gyrotron; superheterodyne receiver; vacuum electron tubes; Bandwidth; Electrons; Frequency measurement; Gyrotrons; Magnetic field measurement; Oscillators; Power generation; Signal resolution; Spectroscopy; Time measurement;
  • fLanguage
    English
  • Journal_Title
    Potentials, IEEE
  • Publisher
    ieee
  • ISSN
    0278-6648
  • Type

    jour

  • DOI
    10.1109/MP.2007.4280329
  • Filename
    4280329