• DocumentCode
    1089806
  • Title

    Accurate design methodology to prevent crosstalk

  • Author

    Chen, C.H. ; Huang, W.T. ; Chou, C.T. ; Lu, C.H.

  • Author_Institution
    Inst. of Health Care Manage., Central Taiwan Univ. of Sci. & Technol., Taichung
  • Volume
    43
  • Issue
    3
  • fYear
    2007
  • Firstpage
    149
  • Lastpage
    150
  • Abstract
    Presented are the effects of a guard trace with the optimal number of grounded vias that gives maximum efficiency for preventing crosstalk in parallel double micro-strip lines in a high-speed printed circuit board layout. Compared to a guard trace with two terminal grounded vias, the near-end crosstalk is reduced from 95 to 30 mV and the far-end crosstalk is reduced from 121 to 56 mV
  • Keywords
    crosstalk; microstrip lines; printed circuit layout; far-end crosstalk; grounded vias; guard trace; high-speed printed circuit board layout; near-end crosstalk; parallel double microstrip lines;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • Filename
    4087782